Home Site Map Contact Us
Paralan CorporationMaking SCSI WorkPurchase SCSI products online at the Paralan Store
About Paralan        SCSI Products        Literature        About SCSI        Support        News        How to Buy
paralan home

68-Conductor SCSI Quiet Cable™ Pinout for LVD/MSE SCSI

Cable Pair Location:   SCSI 68-Conductor pinout for LVD/MSE SCSI showing the accepted SCSI standard: REQ and ACK in the center, control lines in the middle layer and data lines in the outside layer of the cable

See also 50-Conductor SCSI Pinout for SE and HVD Interface
See also 68-Conductor SCSI Pinout for SE and HVD Interface

 

PIN# CABLE
PAIR
SE/LVD
1 30 SR/+DB12
2 31 SR/+DB13
3 32 SR/+DB14
4 33 SR/+DB15
5 34 SR/+DBP1
6 16 SR/+DB0
7 17 SR/+DB1
8 18 SR/+DB2
9 19 SR/+DB3
10 20 SR/+DB4
11 21 SR/+DB5
12 22 SR/+DB6
13 23 SR/+DB7
14 24 SR/+P_CRCA
15 25 GND/GND
16 15 DIFFSENSE
17 14 TPWR/TPWR
18 13 TPWR/TPWR
19 12 RSVD/RSVD
20 5 GND/GND
21 6 SR/+ATN
22 7 GND/GND
23 4 SR/+BSY
24 3 SR/+ACK
25 8 SR/+RST
26 9 SR/+MSG
27 10 SR/+SEL
28 2 SR/+C/D
29 1 SR/+REQ
30 11 SR/+I/0
31 26 SR/+DB8
32 27 SR/+DB9
33 28 SR/+DB10
34 29 SR/+DB11
PIN# CABLE
PAIR
SE/LVD
35 30 -DB12/-DB12
36 31 -DB13/-DB13
37 32 -DB14/-DB14
38 33 -DB15/-DB15
39 34 -DBP1/-DBP1
40 16 -DB0/-DB0
41 17 -DB1/-DB1
42 18 -DB2/-DB2
43 19 -DB3/-DB3
44 20 -DB4/-DB4
45 21 -DB5/-DB5
46 22 -DB6/-DB6
47 23 -DB7/-DB7
48 24 -DBP/-P_CRCA
49 25 GND/GND
50 15 GND/GND
51 14 TPWR/TPWR
52 13 TPWR/TPWR
53 12 RSVD/RSVD
54 5 GND/GND
55 6 -ATN/-ATN
56 7 GND/GND
57 4 -BSY/-BSY
58 3 -ACK/-ACK
59 8 -RST/-RST
60 9 -MSG/-MSG
61 10 -SEL/-SEL
62 2 -C/D/-C/D
63 1 -REQ/-REQ
64 11 -I/O/-I/O
65 26 -DB8/-DB8
66 27 -DB9/-DB9
67 28 -DB10/-DB10
68 29 -DB11/-DB11

For more detailed information on SCSI cabling including connector types, see:

  • SCSI Quiet Cable™ The secret of SCSI Quiet Cable is that they are built according to the SCSI specification, consisting of 25 or 34 twisted pairs of multi-stranded 28-gauge flexible copper wires.

For an overview of SCSI cabling, see:

And for information on how to verify SCSI cable performance, see:

  • Cable Cautions SCSI whitepaper detailing the need to build SCSI cabling to the correct SCSI specifications.

And for information on how to verify SCSI cable performance, see:

Paralan Corportion address
About Paralan | Products | Literature | About SCSI | Support | News | How to Buy

Paralan Corporation 4655 Ruffner Street, San Diego, CA 92111
Sales: (800) 479-7719 | Tel.: (858) 560-7266 | Fax: (858) 560-8929 | E-mail: info@paralan.com
Copyright 2006-2008 Paralan Corporation